<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Ergonomics</title>
<title_fa>مجله ارگونومی</title_fa>
<short_title>Iran J Ergon</short_title>
<subject>Medical Sciences</subject>
<web_url>http://journal.iehfs.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1960</journal_id_issn>
<journal_id_issn_online>2345-5365</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.53208/IJE</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و ساخت جلیقه خنک‌کننده از مواد تغییر فاز دهنده و ارزیابی کارایی آن در کاهش استرین گرمایی تحت شرایط آزمایشگاهی</title_fa>
	<title>The design and manufacturing of phase change material cooling vests and their effectiveness in reducing thermal strain under laboratory conditions</title>
	<subject_fa>سایر موارد</subject_fa>
	<subject>Other Cases</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;پارافین و آب مواد تغییر فاز شناخته شده‌ای برای کاربرد در جلیقه‌های خنک‌کننده هستند. هدف از انجام این مطالعه طراحی و ساخت جلیقه خنک‌کننده با استفاده از ترکیبات پارافین تجاری و یخ  و سپس تعیین تأثیر آن‌ها بر روی پارامترهای استرین گرمایی تحت شرایط آب و هوایی گرم در اتاقک شرایط جوی بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مواد و روش­ها: &lt;/strong&gt;ابتدا یک جلیقه خنک‌کننده از پارچه پلی‌استر با 17 بسته آلومینیومی طراحی و ساخته شد. هر بسته آلومینیومی با 72 گرم آب و 65 گرم پارافین تهیه‌شده پر شد. سپس 10 نفر از دانشجویان در اتاقک شرایط جوی تحت شرایط گرم (دمای خشک = &lt;sup&gt;&lt;span dir=&quot;LTR&quot;&gt;O&lt;/span&gt;&lt;/sup&gt;&lt;span dir=&quot;LTR&quot;&gt;C&lt;/span&gt;40 و رطوبت نسبی = 40%) آزمون را با جلیقه خنک‌کننده و بدون جلیقه خنک‌کننده در دو شدت فعالیت سبک (8/2 کیلومتر در ساعت) و متوسط (8/4 کیلومتر در ساعت) بر روی تردمیل انجام دادند. در هر مرحله از آزمون، مدت استراحت 30 دقیقه و مدت فعالیت بر روی تردمیل نیز 30 دقیقه بود. در طول انجام آزمون نیز ضربان قلب، دمای دهانی و دمای پوست اندازه‌گیری شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; گرمای نهان پارافین تهیه‌شده &lt;span dir=&quot;LTR&quot;&gt;  kJ/kg&lt;/span&gt;108 و پیک نقطه ذوب &lt;sup&gt;&lt;span dir=&quot;LTR&quot;&gt;0&lt;/span&gt;&lt;/sup&gt;&lt;span dir=&quot;LTR&quot;&gt;C&lt;/span&gt; 30 بود. نتایج آنالیز آماری نشان داد که اختلاف میانگین پارامترهای ضربان قلب، دمای دهانی، دمای پوست، میزان تعریق افراد در هنگام فعالیت با جلیقه خنک‌کننده و فعالیت بدون جلیقه خنک‌کننده در هر دو شدت فعالیت معنی‌دار بود (&lt;span dir=&quot;LTR&quot;&gt;p&lt;0.05&lt;/span&gt;).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; جلیقه خنک‌کننده محتوی پارافین و یخ می‌تواند استرین حرارتی را از طریق کاهش دادن ضربان قلب، دمای دهانی، دمای پوست و میزان تعریق کاهش دهد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Introduction:&lt;/strong&gt; Water and paraffin are well-known phase change materials used in the manufacturing of cooling vests. The present study was conducted to design and make a cooling vest using commercial paraffin compounds and ice and to then examine their effect on thermal strain parameters in hot climate conditions in a climate chamber.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and Methods: &lt;/strong&gt;A cooling vest was first made with polyester fabric and containing 17 aluminum packs. Each &lt;a name=&quot;OLE_LINK59&quot;&gt;aluminum&lt;/a&gt; pack was filled with 72 g of water and 65 g of prepared paraffin. A total of 10 male students then performed a treadmill exercise in hot climate conditions in a climate chamber (ambient temperature (TA) = 40 &lt;sup&gt;0&lt;/sup&gt;C and relative humidity (RH) = 40%) once with and once without wearing the cooling vest and at two levels of exercise intensity, including a light intensity (2.8 kph) and a moderate intensity (4.8 kph) exercise. Each stage of the experiment involved 30 minutes of rest and 30 minutes of exercise on the treadmill. Participants’ heart rate, oral and skin temperature and sweat rate were measured throughout the study.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Result:&lt;/strong&gt; The latent heat of the prepared paraffin was 108 kJ/kg and the peak melting point was 30 °C. Significant differences were observed between participants’ mean heart rate, oral and skin temperature and sweat rate at both exercise intensities and both with and without the cooling vest (P&lt;0.05).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; The use of a cooling vest containing paraffin and ice can reduce thermal strain through reducing the heart rate, oral and skin temperature and sweat rate.&lt;/p&gt;
</abstract>
	<keyword_fa>جلیقه خنک‌کننده, مواد تغییر فاز, استرین حرارتی, شرایط دمایی گرم</keyword_fa>
	<keyword>Cooling vest, phase change material, thermal strain, hot climate conditions</keyword>
	<start_page>1</start_page>
	<end_page>11</end_page>
	<web_url>http://journal.iehfs.ir/browse.php?a_code=A-10-311-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Saeed </first_name>
	<middle_name></middle_name>
	<last_name>Yazdani Rad</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدانی راد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846003000</code>
	<orcid>10031947532846003000</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد گروه  مهندسی بهداشت حرفه‌ای دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان.ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Habibollah </first_name>
	<middle_name></middle_name>
	<last_name>Dehghan</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب الله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دهقان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846003001</code>
	<orcid>10031947532846003001</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Occupational Health Engineering, School of Health, Isfahan University of Medical Sciences Email: ha_dehghan@hlth.mui.ac.ir </affiliation>
	<affiliation_fa> استادیار گروه مهندسی بهداشت حرفه‌ای  دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان.ایران. پست الکترونیکی: ha_dehghan@hlth.mui.ac.ir </affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
