<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Ergonomics</title>
<title_fa>مجله ارگونومی</title_fa>
<short_title>Iran J Ergon</short_title>
<subject>Medical Sciences</subject>
<web_url>http://journal.iehfs.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1960</journal_id_issn>
<journal_id_issn_online>2345-5365</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.53208/IJE</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر جلیقه‌های خنک‌کننده بر زمان واکنش و استرین حرارتی افراد در هنگام پوشیدن لباس‌های حفاظت شیمیایی-میکروبی-هسته‌ای در شرایط گرم و خشک آزمایشگاهی</title_fa>
	<title>Effects of Cooling Vests on Heat Strain Indicators and Reaction Time while Wearing Protective Clothing Against Chemical, Microbial, and Radioactive Contamination in Hot and Dry Laboratory Conditions</title>
	<subject_fa>سایر موارد</subject_fa>
	<subject>Other Cases</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;هدف از این مطالعه بررسی تأثیر جلیقه&amp;shy;های خنک&#8204;کننده در حین پوشیدن لباس&amp;shy;های محافظتی شیمیایی- میکروبی-هسته&#8204;ای بر استرین حرارتی و زمان واکنش افراد بوده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مواد و روش&amp;shy;ها: &lt;/strong&gt;این مطالعه بر روی 12 دانشجوی مرد با میانگین سنی 2&amp;plusmn;25 و شاخص توده بدنی 5/1&amp;plusmn;23 انجام گرفت. هر یک از دانشجویان به مدت 20 دقیقه در آزمایشگاه شرایط جوی با دمای 35 درجه سانتی&#8204;گراد و رطوبت نسبی 30 درصد بر روی تردمیل با سرعت &lt;span dir=&quot;LTR&quot;&gt;km/h&lt;/span&gt; 4/2 فعالیت نمودند. نمره شاخص استرین فیزیولوژیکی، دمای دهانی، تعداد خطا و زمان پاسخ (&lt;span dir=&quot;LTR&quot;&gt;Reaction time&lt;/span&gt;) در پایان هر دو مرحله اندازه&#8204;گیری شدند و با استفاده از نرم&#8204;افزار &lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt; نتایج مورد تحلیل قرار گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; آزمون &lt;span dir=&quot;LTR&quot;&gt;Wilcoxon&lt;/span&gt; نشان داد که میانگین تفاوت نمره شاخص استرین گرمایی &lt;span dir=&quot;LTR&quot;&gt;(p=0.002)&lt;/span&gt;، دمای دهانی &lt;span dir=&quot;LTR&quot;&gt;(p=0.002)&lt;/span&gt;، زمان پاسخ &lt;span dir=&quot;LTR&quot;&gt;(p=0.002)&lt;/span&gt;، ضربان قلب &lt;span dir=&quot;LTR&quot;&gt;(p=0.002)&lt;/span&gt; و خطا &lt;span dir=&quot;LTR&quot;&gt;(p=0.003)&lt;/span&gt; در دو حالت با و بدون جلیقه خنک&#8204;کننده معنی&#8204;دار بوده است. میانگین شاخص استرین فیزیولوژیکی &lt;span dir=&quot;LTR&quot;&gt;PSI&lt;/span&gt; در حالت بدون جلیقه خنک&#8204;کننده 882/0&amp;plusmn;038/4 و با جلیقه خنک&#8204;کننده 435/0&amp;plusmn;42/1 بود. همچنین میانگین زمان واکنش در حالت بدون جلیقه 0972/0&amp;plusmn;769/0 و با جلیقه 0977/0&amp;plusmn;539/0 بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری:&lt;/strong&gt; یافته&amp;shy;های مطالعه نشان داد که جلیقه&amp;shy;های خنک&#8204;کننده باعث کاهش استرین فیزیولوژیکی، زمان واکنش و میزان خطای افراد می&#8204;شود.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Introduction:&lt;/strong&gt; This study aimed to investigate the effects of cooling vests on heat strain and reaction time while wearing protective clothing against chemical, biological, and radioactive contamination.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;Materials and Methods: Twelve male students with the mean age of 25 &amp;plusmn; 2 years and mean body mass index (BMI) of 23.0 &amp;plusmn; 1.5 kg/m2 were recruited in this experiment. Each student was asked to run on a treadmill at a speed of 2.4 km/h for 20 minutes. The experiments were performed at 35 &amp;deg;C and 30% relative humidity. Physiological strain index score, oral temperature, heart rate, reaction time, and number of errors were measured at the end of the two phases. The findings were analyzed by SPSS.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; According to Wilcoxon test, exercising with and without the cooling vest resulted in significantly different physiological strain index scores (P = 0.02), oral temperature (P = 0.02), reaction time (P = 0.02), heart rate (P = 0.02), and errors (P = 0.03). The mean physiological strain index score was 4.038 &amp;plusmn; 0.882 without the cooling vest and 1.42 &amp;plusmn; 0.435 with the cooling vest. The mean reaction times with and without the cooling vest were 0.539 &amp;plusmn; 0.977 and 0.769 &amp;plusmn; 0.0972, respectively.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; The results of this study showed that using a cooling vest reduced the physiological strain, reaction time, and error rates in workers.&lt;/p&gt;
</abstract>
	<keyword_fa>استرین حرارتی, زمان واکنش, شاخص استرین فیزیولوژیکی, لباس های محافظتی</keyword_fa>
	<keyword>Heat strain, Reaction time, Physiological strain index, Protective clothing</keyword>
	<start_page>11</start_page>
	<end_page>20</end_page>
	<web_url>http://journal.iehfs.ir/browse.php?a_code=A-10-181-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Habibollah </first_name>
	<middle_name></middle_name>
	<last_name>Dehghan Shahreza</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب الله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دهقان شهرضا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ha_dehghan@hlth.mui.ac.ir</email>
	<code>10031947532846003422</code>
	<orcid>10031947532846003422</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Firouz</first_name>
	<middle_name></middle_name>
	<last_name>Valipour</last_name>
	<suffix></suffix>
	<first_name_fa>فیروز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ولی پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>firouzvalipour@gmali.com</email>
	<code>10031947532846003423</code>
	<orcid>10031947532846003423</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Khalili Gorji</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خلیلی گرجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Hossein_khalili@hlth.mui.ac.ir</email>
	<code>10031947532846003424</code>
	<orcid>10031947532846003424</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of health, Isfahan University of Medical Sciences, Isfahan, Iran. </affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Behzad</first_name>
	<middle_name></middle_name>
	<last_name>Mahaki</last_name>
	<suffix></suffix>
	<first_name_fa>بهزاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>behzad.mahaki@gmail.com</email>
	<code>10031947532846003425</code>
	<orcid>10031947532846003425</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
