<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Ergonomics</title>
<title_fa>مجله ارگونومی</title_fa>
<short_title>Iran J Ergon</short_title>
<subject>Medical Sciences</subject>
<web_url>http://journal.iehfs.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-1960</journal_id_issn>
<journal_id_issn_online>2345-5365</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.53208/IJE</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1405</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2026</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و مدل‌سازی کفش برای بیماران مبتلابه عارضه افتادگی پنجه پا، با استفاده از تجزیه‌وتحلیل آماری و ارگونومی</title_fa>
	<title>Designing and Modeling Shoes for Patients with Drop Foot Using Statistical and Ergonomic Analysis</title>
	<subject_fa> ارگونومی در طراحی</subject_fa>
	<subject>Ergonomics in Design</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div class=&quot;rounded&quot; style=&quot;background:#eeeeee;border:1px solid #cccccc;padding:5px 10px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;position:relative&quot;&gt;&lt;span style=&quot;top:-1.0pt&quot;&gt;اهداف:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;افتادگی پا ناشی از اختلالات سیستم عصبی و ... است که می&#8204;تواند الگوی راه&#8204;رفتن را مختل کند. استفاده از تجهیزات توان&#8204;بخشی مناسب در بهبود عملکرد حرکتی این بیماران نقش مهمی دارد. هدف این پژوهش ارائه مبانی طراحی یک کفش توان&#8204;بخشی برای بهبود برخی شاخص&#8204;های بیومکانیکی، شامل زاویه پنجه، گشتاور عضلانی و طول گام در بیماران مبتلابه افتادگی پا بود. یافته&#8204;های این پژوهش با هدف دستیابی به مبانی طراحی است و در مرحله بعد، با افزایش تعداد نمونه&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&amp;not;ها، باید وارد مرحله طراحی برای تولید شود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;position:relative&quot;&gt;&lt;span style=&quot;top:-1.0pt&quot;&gt;روش &#8204;&#8204;&#8204;کار: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;این پژوهش یک مطالعه موردی مبتنی&#8204;بر شبیه&#8204;سازی بیومکانیکی بود. متغیرهای مورد ارزیابی شامل زاویه پنجه پا، گشتاور عضله تیبیالیس قدامی و طول گام بودند. این متغیرها با استفاده از مدل&#8204;سازی اسکلتی عضلانی در نرم&#8204;افزار &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;OpenSim&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; و تحلیل اجزای محدود در محیط &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ABAQUS&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt; استخراج شدند. داده&#8204;ها در چهار وضعیت شبیه&#8204;سازی (کفش طراحی&#8204;شده، ارتوز مرجع، بیمار و فرد سالم) مقایسه شدند. تحلیل داده&#8204;ها به&#8204;صورت توصیفی و براساس بررسی و مقایسه روند تغییرات شاخص&#8204;های بیومکانیکی انجام شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;position:relative&quot;&gt;&lt;span style=&quot;top:-1.0pt&quot;&gt;یافته&#8204;ها: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;نتایج نشان داد استفاده از کفش طراحی&#8204;شده موجب بهبود حدود 80 درصدی زاویه پنجه پا در فاز نوسان شد. همچنین، گشتاور عضله تیبیالیس قدامی حدود 85 درصد افزایش یافت و طول گام نسبت به وضعیت بیمار بهبود نشان داد. این تغییرات بیانگر بهبود نسبی شاخص&#8204;های بیومکانیکی مرتبط با راه&#8204;رفتن است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;position:relative&quot;&gt;&lt;span style=&quot;top:-1.0pt&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&amp;nbsp;این پژوهش سه شاخص کلیدی بیومکانیکی، شامل طول گام، گشتاور عضله تیبیالیس قدامی و زاویه پنجه پا را بهبود داد. همچنین، نتایج شبیه&#8204;سازی موردی و نتایج آماری توصیفی نشان داد مدل پیشنهادی حرکت سیستماتیک و به&#8204;هم&#8204;تنیده مچ و پنجه&#8204;پای بیماران افتادگی پنجه پا را به&#8204;خوبی تحت کنترل درآورد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;color:#7030a0&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div class=&quot;rounded&quot; style=&quot;background:#eeeeee;border:1px solid #cccccc;padding:5px 10px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;b&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;letter-spacing:-.15pt&quot;&gt;Objectives: &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;Foot drop is caused by neurological disorders and traumatic injuries and can impair gait pattern and increase energy expenditure during walking. The use of appropriate rehabilitation devices plays an important role in improving patients&amp;#39; motor performance. This study aimed to provide the design basis for a rehabilitation shoe intended to improve selected biomechanical parameters, including toe angle, muscle torque, and step length in patients with foot drop. The findings of this study are considered preliminary design evidence, and further studies with larger sample sizes are required before moving toward product development and manufacturing.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;b&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;letter-spacing:.15pt&quot;&gt;Methods: &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;letter-spacing:.15pt&quot;&gt;This study was a case-based biomechanical simulation investigation. The evaluated variables included toe angle, tibialis anterior muscle torque, and step length. These variables were extracted using musculoskeletal modeling in OpenSim software and finite element analysis in ABAQUS. The obtained data were compared across four simulation conditions: the designed shoe, the reference ankle-foot orthosis, the patient condition, and the healthy control. Data analysis was performed descriptively by evaluating and comparing biomechanical trend changes.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;b&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;letter-spacing:-.15pt&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; The use of the designed shoe improved toe angle during the swing phase by approximately 80% compared with the patient condition. In addition, tibialis anterior muscle torque increased by approximately 85%, and step length also improved relative to the patient&amp;#39;s condition. These findings indicate a relative improvement in gait-related biomechanical parameters in the proposed model.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span style=&quot;color:#990099&quot;&gt;&lt;span style=&quot;letter-spacing:-.1pt&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;color:black&quot;&gt;The proposed design improved three key biomechanical parameters, including step length, tibialis anterior muscle torque, and toe angle. Furthermore, the case-based simulation and descriptive statistical findings suggested that the proposed model has the potential to effectively control the coordinated movement of the ankle and forefoot in individuals with foot drop.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>افتادگی پنجه پا, ارتوز مچ پا, بیومکانیک, تحلیل راه‌رفتن, توان‌بخشی</keyword_fa>
	<keyword>Ankle-foot orthosis, Biomechanics, Foot drop, Gait analysis, Rehabilitation</keyword>
	<start_page>111</start_page>
	<end_page>120</end_page>
	<web_url>http://journal.iehfs.ir/browse.php?a_code=A-10-7557-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Samaneh</first_name>
	<middle_name></middle_name>
	<last_name>Taheri</last_name>
	<suffix></suffix>
	<first_name_fa>سمانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طاهری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Taheri.samanee@gmail.com</email>
	<code></code>
	<orcid>0009-0000-5776-4704</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Industrial Department, Industrial and Management Research Center, Malek Ashtar University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی صنایع، دانشکده مدیریت و صنایع، دانشگاه صنعتی مالک اشتر، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Karim</first_name>
	<middle_name></middle_name>
	<last_name>Atashgar</last_name>
	<suffix></suffix>
	<first_name_fa>کریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آتشگر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>atashgar@iust.ac.ir</email>
	<code></code>
	<orcid>0000-0003-3738-2703</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Mechanic Department, Mechanic and Material Research Center, Malek Ashtar University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مکانیک، دانشکده مکانیک، دانشگاه صنعتی مالک‌اشتر، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammadreza</first_name>
	<middle_name></middle_name>
	<last_name>Zamani</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زمانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a_mrzamani@mut.ac.ir</email>
	<code></code>
	<orcid>0009-0002-8211-8645</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Mechanic Department, Mechanic and Material Research Center, Malek Ashtar University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مکانیک، دانشکده مکانیک، دانشگاه صنعتی مالک‌اشتر، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
